عنوان Low-Frequency Oscillations Damping in an Inverter-Based Islanded Microgrid Using the Virtual Synchronous Generator Concept
نوع پژوهش پایان نامه
کلیدواژه‌ها Low-frequency oscillations; virtual synchronous generator (VSG); grid- forming inverter; islanded microgrid; supplementary damping control;
چکیده Low-frequency oscillations occur in islanded microgrids when the dynamics of synchronous generators (SG) interact with grid-forming (GFM) and grid-following (GFL) converters. This thesis examines a local supplementary damping control for an islanded microgrid comprising a synchronous generator, a virtual synchronous generator (VSG)-based grid-forming inverter, and a phase-locked-loop (PLL)-based grid- following inverter. This damping signal is proposed from the local VSG frequency deviation Δω and injected into the VSG input-power pathway before the virtual swing- equation dynamics. The supplementary controller modulates the auxiliary active-power signal while maintaining the natural VSG inertia, damping, and frequency-power control structure. A MATLAB/Simulink model is developed and evaluated with an 8kW resistive load connected. The performance of five controller structures is evaluated: a filtered proportional-integral-derivative controller, a one-stage washout/lead-lag controller, a two-stage washout/lead-lag controller, a one-stage washout/lead-lag controller cascaded with a filtered PID, and a two-stage washout/lead-lag controller cascaded with a filtered PID. The controller parameters are optimized using bounded particle swarm optimization, with the integral of time-weighted absolute error (ITAE) of the centered VSG power-balance deviation as the primary objective. ITAE, RMS deviation, peak deviation, settling time, spectral amplitude, damping estimates derived from the signal, and final frequencies are used to compare the controllers. The two-stage washout/lead–lag controller, cascaded with a filtered PID controller, offers the best retained performance among the designs investigated. It reduces ITAE from 70.28 to 0.559 W·s², RMS deviation from 454.2 to 17.17 W, peak deviation from 2030 to 125.8 W, and settling time from 0.821 to 0.050 s. The auxiliary control signal is bounded and drops sharply once the corrective action is taken. The results show that the suggested supplementary damping strategy can effectively reduce post-disturbance oscillations and improve frequency recovery in the analyzed microgrid model operating in island mode. However, the results apply only to the studied model, operating conditions, disturbance conditions, and optimization technique. The proposed approach needs further testing and validation in experimental or real-time studies to prove its robustness.
پژوهشگران حسن بیورانی (استاد راهنما)، اسماعیل طالب طالب صالح (دانشجو)، شراره رحیمی (استاد مشاور)