1403/02/07
روناک دقیق

روناک دقیق

مرتبه علمی: دانشیار
ارکید:
تحصیلات: دکترای تخصصی
اسکاپوس: 55405375500
دانشکده: دانشکده مهندسی
نشانی:
تلفن:

مشخصات پژوهش

عنوان
Parametric studies of an active solar water heating system with various types of PVT collectors
نوع پژوهش
JournalPaper
کلیدواژه‌ها
PV/T collectors; TRNSYS simulation; solar water heater; solar fraction; packing factor; glazed and unglazed collector.
سال
2015
مجله SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES
شناسه DOI
پژوهشگران Roonak Daghigh ، Mohd Hafidz Ruslan ، Kamaruzzaman Sopian

چکیده

This study simulated active photovoltaic thermal solar collectors (PV/T) for hot water production using TRNSYS. The PV/T collectors consist of the amorphous, monocrystalline and polycrystalline. The long-term performances for the glazed and unglazed PV/T collectors were also evaluated. In this simulation, the design parameters used were collector area of 4 m2, collector slope angle of 15 degree and mass flow rate to the collector area ratio of 8–20 kg/hm2. In addition the tank height between 0.9 m to 1.1 m for unglazed PV/T collectors and 0.9 m to 1 m for glazed collectors, as well as the storage tank volume between 200 and 300 L has been used. The climate parameters used were solar radiation levels range of 4–4.9 kWh/m2, the mean ambient temperature in the range of 25–28◦C. The results of the simulation indicated that there was an increase in solar fraction and electrical power output of the active PV/T hot water system.